Research Article

Experimental Studies for the VVER-440/213 Bubble Condenser System for Kola NPP at the Integral Test Facility BC V-213

Table 6

Initial and boundary conditions of the tests.

Test facility parameterTest 1Test 4Test 5Test 7Test 9Test 12

Fully filled with water °CFully filled with water °CFully filled with water °CWater level 2.325 m °CWater level 2.325 m °CFully filled with water °C
Fully filled with water °CFully filled with water °CFully filled with water °CWater level 1.370 m °CWater level 1.370 m °CIt is not used
It is not usedIt is not usedIt is not usedSteam °CSteam °CIt is not used
It is not usedIt is not usedIt is not usedIt is not usedIt is not usedIt is not used
Water level 1.270 m °CWater level 1.270 m °CWater level 1.270 m °CSteam °CSteam °CWater level 3.000 m °C
System pressure12.5 MPa12.5 MPa12.5 MPa4.7 MPa4.7 MPa12.5 MPa
Additional supply of steam (  MPa, °C) into It is not usedIt is not usedIt is not used0.4 kg/s (100–500 s) 0.2 kg/s (after)0.4 kg/s (100–500 s) 0.2 kg/s (after)It is not used
Position of discharge nozzleMiddleNearFarFarFearMiddle
Nozzle diameter45 mm56 mm56 mm56 mm56 mm4 mm