| No. | Parameter | Tests | Test 4 LB LOCA | Test 5 LB LOCA | Test 1 LB LOCA | Test 7 MSLB | Test 9 MSLB | Test 12 SB LOCA |
| (1) | Maximum absolute pressure in box , (MPa) | 0,202 | 0,214 | 0,197 | 0,1835 | 0,175 | 0,111 | (2) | Time of achievement of maximum pressure in box , (s) | 8,07–9,77 | 8,89 | 70–90 | 90–100 | 90.5–96 | 353–388 | (3) | Maximum pressure difference across BC, (kPa) | 14,55 | 15,73 | 11,62 | 7,8 | 7,7 | 4,9 | (4) | Maximum absolute pressure in air trap , (MPa) | 0,193 | 0,200 | 0,191 | 0,177 | 0,169 | 0,106 | (5) | Maximum temperature in box , (°C) | 120 | 122 | 120 | 118 | 118 | 86 | (6) | Maximum temperature of BC water, (°C) | 78 | 78 | 60 | 56 | 63 | 38,5 | (7) | Time of check valve closure, (s) | 90 | 87 | 114 | 212 | 185 | 2240 | (8) | Absolute pressure in box when relief valve opened, (MPa) | 0,19 | 0,17 | 0,191 | 0,174 | 0,167 | 0,106 | (9) | Time of relief valve opening, (s) | 88,6 | 90,3 | 115 | 207,6 | 180 | 2300 | (10) | Occurrence of reverse flow from BC | no | yes | no | no | no | no | (11) | Break location | near | far | middle | far | near | middle |
|
|