Research Article

Trace Code Validation for BWR Spray Cooling Injection and CCFL Condition Based on GÖTA Facility Experiments

Table 3

View factors used in TRACE.

Rod group 1A Rod group 1B Rod group 2Rod group 3Rod group 4Rod group 5Canister wall

Rod group 1A 0,00000,19320,10100,20330,01300,00000,4189
Rod group 1B 0,19320,00000,10100,20330,01300,00000,4189
Rod group 20,10100,10100,00000,33340,02570,00240,3759
Rod group 30,20330,20330,33340,00000,24980,01430,0496
Rod group 40,01300,01300,02570,24980,00000,19130,0103
Rod group 50,00000,00000,00240,01430,19130,00000,0063
Canister wall0,41890,41890,37590,04960,01030,00630,0000