Table of Contents Author Guidelines Submit a Manuscript
Science and Technology of Nuclear Installations
Volume 2012, Article ID 439374, 12 pages
http://dx.doi.org/10.1155/2012/439374
Research Article

The Integral Test Facility Karlstein

Department PTBD-G, AREVA NP GmbH Germany, Kaiserleistr 29, 63067 Offenbach, Germany

Received 23 March 2011; Accepted 3 September 2011

Academic Editor: Klaus Umminger

Copyright © 2012 Stephan Leyer and Michael Wich. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. Brosche and J. Mattern, “The BWR 1000—an advanced boiling water reactor with medium power,” VGB Power Tech 11/99.
  2. Z. Stosic, W. Brettschuh, and U. Stoll, “Boiling water reactor with innovative safety concept: the Generation III+ SWR 1000,” Nuclear Engineering and Design, vol. 238, no. 8, pp. 1863–1901, 2008. View at Publisher · View at Google Scholar · View at Scopus
  3. M. Huggenberger, C. Aubert, T. Bandurski, J. Dreier, H. J. Strassberger, and G. Yadigaroglu, “ESBWR related passive decay heat removal test in PANDA,” in Proceedings of the 7th International Conference on Nuclear Engineering (ICONE-7), Tokyo, Japan, April 1999.
  4. M. Huggenberger, C. Aubert, J. Dreier, O. Fischer, H. J. Strassberger, and G. Yadigaroglu, “New passive decay heat removal test in PANDA,” in Proceedings of the 6th International Conference on Nuclear Engineering (ICONE-7), San Diego, Calif, USA, May 1998.
  5. M. Ishii, H. J. Yoon, Y. Xu, and S. T. Revankar, “Modular simplified boiling water reactor design with passive safety systems,” in Proceedings of the International Atomic Energy Agency Meeting (IAEA '05), 2005.
  6. G. Yadigaroglu, “Scaling of SBWR related tests,” GE, NEDC-32288, 1994.
  7. R. Hamazaki et al., “The enhanced severe accident mitigation systems for a BWR,” in Proceedings of the 13th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-13), Kanazawa City, Japan, September 2009.
  8. Y. Kojima, K. Arai, T. Kurita et al., “Performance of horizontal U-tube type passive containment cooling system in a BWR,” in International Congress on Advances in Nuclear Power Plants (ICAPP '10), pp. 1135–1142, San Diego, Calif, USA, June 2010. View at Scopus
  9. K. B Welter, S. M. Bajorek, and J. Reyes, “APEX-AP1000 confirmatory testing to support AP1000 design certification,” United States Nuclear Regulatory Commission number NUREG-1826, 2005. View at Google Scholar
  10. J. N. Reyes, J. T. Groome, A. Y. Lafi, D. Wachs, and C. Ellis, “PTS thermal hydraulic testing in the OSU APEX facility,” International Journal of Pressure Vessels and Piping, vol. 78, no. 2-3, pp. 185–196, 2001. View at Publisher · View at Google Scholar · View at Scopus
  11. A.Y. Lafi and J. N. Reyes, “Two-inch cold leg break tests in APEX and ROSA/AP600 comparative study,” in Proceedings of the 9th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-9), San Francisco, Calif, USA, October 1999.
  12. D. E. Bessette and M. Di Marzo, “Transition from depressurization to long term cooling in AP600 scaled integral test facilities,” Nuclear Engineering and Design, vol. 188, no. 3, pp. 331–344, 1999. View at Publisher · View at Google Scholar · View at Scopus
  13. R. F. Wright, “Simulated AP1000 response to design basis small-break LOCA events in the APEX-1000 test facility,” Nuclear Engineering and Technology, vol. 39, no. 4, pp. 287–299, 2007. View at Google Scholar
  14. G. Bianconi and M. Rigamonti, “Scaling, design,and verification of SPES-2,” Westinghouse Corporation, Piacenza, Italy, WCAP-13277 Rev.1., 1992.
  15. S. Leyer, M. Wich, and H. Schafer, “SWR 1000 integral and full scale tests of the passive safety systems,” in Proceedings of the International Conference on Advances in Nuclear Power Plants (ICAPP '08), pp. 87–92, Anaheim, Calif, USA, June 2008. View at Scopus
  16. S. Leyer, F. Maisberger, B. Schaub et al., “Full scale steady state component tests of the SWR 1000 fuel pool cooler at the INKA test facility,” in Proceedings of the Annual Meeting of Nucluar Technology, Dresden, Germany, May 2009.
  17. S. Leyer, F. Maisberger, V. Herbst, M. Doll, M. Wich, and T. Wagner, “Status of the full scale component testing of the KERENA emergency condenser and containment cooling condenser,” in Proceedings of the International Conference on Advances in Nuclear Power Plants (ICAPP '10), p. 5, San Diego, Calif, USA, June 2010.
  18. T. Wagner, M. Wich, M. Doll, V. Herbst, and S. Uhrig, “Tests with the emergency condenser at the integral test stand Karlstein for KERENA,” in Proceedings of the Annual Meeting of Nucluar Technology, Berlin, Germany, May 2010.
  19. T. Wagner, M. Wich, M. Doll, and S. Leyer, “Full scale tests with the passive core flooding system and the emergency condenser at the integral test stand Karlstein for KERENATM,” in Proceedings of the International Conference on Advances in Nuclear Power Plants (ICAPP '10), Nice, France, May 2011.