Review Article

Analyses of the OSU-MASLWR Experimental Test Facility

Table 1

MASLWR steady-state operating conditions [810].

Primary side
 Reactor thermal power150 MW
 Primary pressure7.60 MPa
 Primary mass flow rate597 kg/s
 Reactor inlet temperature491.80 K
 Reactor outlet temperature544.30 K
 Saturation temperature565 K
 Reactor outlet void fraction0.00%

Secondary side
 Steam pressure1.50 MPa
 Steam outlet quality1
 Steam temperature481.40 K
 Saturation temperature471.60 K
 Feedwater temperature310 K
 Feedwater flow rate56.10 kg/s