Review Article
Analyses of the OSU-MASLWR Experimental Test Facility
Table 1
MASLWR steady-state operating conditions [
8–
10].
| Primary side | | Reactor thermal power | 150 MW | Primary pressure | 7.60 MPa | Primary mass flow rate | 597 kg/s | Reactor inlet temperature | 491.80 K | Reactor outlet temperature | 544.30 K | Saturation temperature | 565 K | Reactor outlet void fraction | 0.00% |
| Secondary side | | Steam pressure | 1.50 MPa | Steam outlet quality | 1 | Steam temperature | 481.40 K | Saturation temperature | 471.60 K | Feedwater temperature | 310 K | Feedwater flow rate | 56.10 kg/s |
|
|