Research Article

Analysis of Void Fraction Distribution and Departure from Nucleate Boiling in Single Subchannel and Bundle Geometries Using Subchannel, System, and Computational Fluid Dynamics Codes

Table 2

Geometrical parameters of each subchannel [2].

Subchannel type
Typical (S1)Thimble (S2)Side (S3)Corner (S4)

Flow area, mm2107.098107.09868.46442.592
Heated perimeter, mm29.84522.38414.9237.461
Wetted perimeter, mm54.64554.64544.92333.161