Research Article

Benchmark of Subchannel Code VIPRE-W with PSBT Void and Temperature Test Data

Table 6

Summary of steady-state void comparison based on EPRI void model.

Bundle testNumber of pointsMeasured-predicted void fraction
MeanStandard deviation
LowerMiddleUpperLowerMiddleUpper

B574−0.023−0.0220.0310.0290.0460.039
B6740.0260.0510.0720.0490.0380.044
B774−0.074−0.0430.0190.0350.0440.028