Research Article
PMK-2, the First Integral Thermal-Hydraulics Tests for the Safety Evaluation of VVER-440/213 Nuclear Power Plants
Table 7
Cladding temperatures in OAH-C1 test.
| Identification | Location rod no./elevation ā/m | Temperature excursion | Time s | LE11 m | Temperature K |
| TE14 | 6/2.994 | Starts | 1131 | 2.774 | 543.4 | | normal | Max. | 1156 | 2.761 | 628.4 | | | End | 1175 | 2.696 | 549.9 |
| TE15 | 11/3.444 | Starts | 1118 | 2.968 | 544.4 | | wall | 1. max. | 1180 | 3.232 | 684.0 | | | 2. max. | 1263 | 3.210 | 692.7 | | | 3. max. | 1515 | 2.970 | 718.0 | | | End | 1585 | 2.874 | 546.0 |
| TE16 | 1/3.444 | Starts | 1119 | 2.947 | 544.7 | | central | 1. max. | 1179 | 3.144 | 697.0 | | | 2. max. | 1260 | 3.145 | 702.4 | | | 3. max. | 1515 | 2.970 | 739.2 | | | End | 1592 | 3.141 | 546.0 |
| TE17 | 16/3.444 | Starts | 1115 | 3.021 | 544.4 | | corner | 1. max. | 1179 | 3.144 | 680.7 | | | 2. max. | 1259 | 3.068 | 681.7 | | | 3. max. | 1514 | 2.886 | 713.2 | | | End | 1585 | 2.874 | 546.0 |
| TE18 | 2/3.444 | Starts | 1117 | 2.985 | 544.4 | | normal | 1. max. | 1180 | 3.232 | 701.0 | | | 2. max. | 1261 | 3.184 | 708.7 | | | 3. max. | 1515 | 2.970 | 737.7 | | | End | 1590 | 3.006 | 546.0 |