Research Article

Uncertainty and Sensitivity Analyses of a Pebble Bed HTGR Loss of Cooling Event

Table 2

PEBBED-THERMIX CRP-5 DLOFC uncertainty study cases.

Number of model runsInput parameter sampling methodInput parameter distribution typeModel input parameters varied

100Latin HypercubeUniformPower, RIT, decay heat only
100Latin HypercubeUniformSpecific heat and thermal conductivity only
100Latin HypercubeUniformAll
100Latin HypercubeGaussian/normalAll
200Latin HypercubeGaussian/normalAll
200Simple RandomGaussian/normalAll