Research Article
Assessment of CTF Boiling Transition and Critical Heat Flux Modeling Capabilities Using the OECD/NRC BFBT and PSBT Benchmark Databases
Table 2
Results for test case SA505500.
|
SA505500 |
Measured data |
Without turbulent mixing and void drift | Lahey and Moody model [29] | Two-phase mixing enhancement by Beus | Mixing coefficient of 0.03 | Mixing coefficient by Rogers and Rosehart [30] |
| Critical power | 6.13 MW | 6.67 MW | 8.25 MW | 7.59 MW | Radial location | Peripheral rod | Peripheral rod | Central rod next to water channel | Central rod next to water channel | Axial location | 3.521 m | 3.335 m | 3.612 m | 3.612 m |
|
|