Research Article
Analysis of the Processes in Spent Fuel Pools in Case of Loss of Heat Removal due to Water Leakage
Table 1
Parameters of SFA in SFP.
| Groups of SFAs in model | Amount of SFAs in group | Assumed storage time in SFP | SFAs decay heat, W | Group power, kW |
| ROD1 | 166 | 8 days | 5210 | 864.9 | ROD2 | 1182 | 137 days | 1281 | 1514.1 | ROD3 | 892 | 2 years | 489 | 436.2 | ROD4 | 5661 | 3 year | 254 | 1437.9 |