Research Article
Uncertainty and Sensitivity Studies with TRACE-SUSA and TRACE-DAKOTA by Means of Steady State BFBT Data
Table 3
Input parameter combinations and uncertainty results for the single-phase flow pressure drop cases.
| Case (P700x) | Poutlet (bar) | MFR (t/h) | Tinlet (K) | Exp. (Pa) | Mean (Pa) | Max (Pa) | Min (Pa) | SD (Pa) | Error (%) |
| 02 | 2.0 | 14.5 | 311.65 | 1920 | 1872 | 2010 | 1762 | 57 | −2.49 | 1881 | 1928 | 1831 | 24 | −2.05 | 07 | 2.0 | 39.7 | 309.35 | 10990 | 10356 | 11266 | 9647 | 372 | −5.77 | 10371 | 10732 | 10009 | 181 | −5.63 | 13 | 2.0 | 9.9 | 449.65 | 740 | 1004 | 1068 | 958 | 25 | 35.70 | 1010 | 1053 | 961 | 22 | 35.43 | 16 | 9.8 | 24.8 | 449.35 | 4060 | 4252 | 4618 | 3988 | 144 | 4.73 | 4293 | 4427 | 4079 | 97 | 5.74 | 30 | 71.6 | 34.7 | 558.85 | 8570 | 8975 | 9793 | 8385 | 318 | 4.73 | 9011 | 9366 | 8625 | 159 | 5.15 | 35 | 71.6 | 64.8 | 557.75 | 22770 | 29588 | 32337 | 27604 | 1072 | 6.55 | 29657 | 30887 | 28221 | 605 | 6.80 |
|
|