Input parameter combinations and uncertainty results for the two-phase flow pressure drop cases.

Case (P600x)Poutlet (bar)MFR (t/h)hsub (kJ/kg) (MW)Exp. (Pa)Mean (Pa)Max (Pa)Min (Pa)SD (Pa)Error (%)

0171.620.253.30.86327400263762695525788264−3.74
263692684025915196−3.76
0871.755.049.03.057657206400068566607551732−2.62
6377466553612971098−2.96
1471.670.150.63.884912709081898174854912817−0.50
9025793822861911835−1.11
2071.645.151.84.363688306400368386601851777−7.01
637126572561955960−7.44
2286.420.250.70.83726830260082658725435262−3.06
259342649225377236−3.34
3086.470.251.45.0761007701013991096409527332160.62
1008101054809557820860.04