Research Article

Long-Term Station Blackout Accident Analyses of a PWR with RELAP5/MOD3.3

Table 1

Set of scenarios analyzed for each of the four depressurization cases.

ScenarioSeal leak per RCP (l/s)LD leak*(l/s)TD AFW pumpPRZ PORVPDP

S0-211.325.68ONNoNo
S0-503.155.68ONNoNo
S0-754.735.68ONNoNo
S0-1006.315.68ONNoNo
S0-1509.465.68ONNoNo
S0-30018.935.68ONNoNo
S0-300p18.935.68ONNoYes
S1-211.325.68Off at 4 hrNoNo
S1-21v11.325.68Off at 4 hrYes (one PORV)No
S1-21v21.325.68Off at 4 hrYes (two PORVs)No
S1-21p1.325.68Off at 4 hrNoYes

When RCS pressures greater than 4.23 MPa.