Research Article

Effect of Flow Blockage on the Coolability during Reflood in a 2 2 Rod Bundle

Table 2

Main test conditions of the blockage tests.

(cm/s)/Test conditions (cm/s) (kPa) (°C) (kW/m)

1.01.03101.557.01.00
1.04101.352.01.50

1.51.55101.352.11.01
1.53101.452.71.50

2.02.06101.451.01.01
2.04101.353.11.51

2.52.56101.450.21.00
2.56101.350.61.50

3.53.43101.454.31.01
3.43101.351.01.51