Research Article
Preliminary Development of Thermal Power Calculation Code H-Power for a Supercritical Water Reactor
Table 1
Comparison of calculation results between H-Power routine and IAPWS-IF97.
| Region | Parameters | Given by | /(m3 kg−1) | /(kJ kg−1) | /(kJ kg−1 K−1) | /(kJ kg−1) |
| Subregion 1 | K | IF97 | 0.00100215168 | 115.331273 | 0.392294792 | 112.324818 | MPa | H-Power | 0.0010021516 | 115.33127302 | 0.3922947924 | 112.32481798 | K | IF97 | | 184.142828 | 0.368563852 | 106.448356 | MPa | H-Power | | 184.14282773 | 0.3685638523 | 106.44835621 |
| Subregion 2 | K | IF97 | 39.4913866 | 2549.91145 | 8.52238967 | 2411.69160 | MPa | H-Power | 39.491386637 | 2549.9114508 | 8.5223896673 | 2411.6915976 | K | IF97 | 0.0311385219 | 6571.22604 | 8.53640523 | 5637.07038 | MPa | H-Power | 0.0311385218 | 6571.2260386 | 8.5364052311 | 5637.0703825 |
| Subregion 3 | K MPa | IF97 | 0.005613 | 2500.75 | 5.0320 | 2366.0 | H-Power | 0.0056134399 | 2500.7519610 | 5.0320333072 | 2366.0291590 | K MPa | IF97 | 0.002487 | 2284.44 | 4.5892 | 2160.1 | H-Power | 0.0024874366 | 2284.4399286 | 4.58922040321 | 2160.0680674 |
| Subregion 5 | K | IF97 | 1.3845509 | 5219.76855 | 9.65408875 | 4527.49310 | MPa | H-Power | 1.3845508987 | 5219.7685512 | 9.6540887533 | 4527.4931018 | K | IF97 | 0.0311385219 | 6571.22604 | 8.53640523 | 5637.07038 | MPa | H-Power | 0.0311385218 | 6571.2260386 | 8.5364052311 | 5637.0703825 |
|
|