Research Article

Preliminary Development of Thermal Power Calculation Code H-Power for a Supercritical Water Reactor

Table 1

Comparison of calculation results between H-Power routine and IAPWS-IF97.

Region Parameters Given by /(m3 kg−1) /(kJ kg−1) /(kJ kg−1 K−1) /(kJ kg−1)

Subregion 1  KIF970.00100215168115.3312730.392294792112.324818
 MPaH-Power0.0010021516115.331273020.3922947924112.32481798
 KIF97 184.1428280.368563852106.448356
 MPaH-Power 184.142827730.3685638523106.44835621

Subregion 2  KIF9739.49138662549.911458.522389672411.69160
 MPaH-Power39.4913866372549.91145088.52238966732411.6915976
 KIF970.03113852196571.226048.536405235637.07038
 MPaH-Power0.03113852186571.22603868.53640523115637.0703825

Subregion 3  K
 MPa
IF970.0056132500.755.03202366.0
H-Power0.00561343992500.75196105.03203330722366.0291590
 K
 MPa
IF970.0024872284.444.58922160.1
H-Power0.00248743662284.43992864.589220403212160.0680674

Subregion 5  KIF971.38455095219.768559.654088754527.49310
 MPaH-Power1.38455089875219.76855129.65408875334527.4931018
 KIF970.03113852196571.226048.536405235637.07038
 MPaH-Power0.03113852186571.22603868.53640523115637.0703825