Test 3 test conditions.

EventConditionHigh-pressure phaseConditioning phaseLow-pressure phase

Break valve opened = 0 s*
Low-pressure scram signal < 12.96 MPa*
Secondary system isolation Scram signal*
Initiation of primary coolant pump coastdown Scram signal*
Initiation of core power decay curve simulationScram signal*
Initiation of HPI coolant injection into pressure vessel upper plenum > 750 K*
Break valve closed < 5 MPa**
Power constant < 5 MPa*
Termination of HPI coolant injection into pressure vessel upper plenum · *
SG’s relief valve depressurization · *
Secondary system isolation < 3.9 MPa*
Break valve reopened > 4.5 MPa**
SG depressurization as AM action  > 623 K*
Initiation of AFW in both loopsAM action signal*
Initiation of ACC system in both loops < 2.6 MPa*
Termination of ACC system in both loops < 1.2 MPa*