Research Article
Applying UPC Scaling-Up Methodology to the LSTF-PKL Counterpart Test
Table 2
Test 3 test conditions.
| Event | Condition | High-pressure phase | Conditioning phase | Low-pressure phase |
| Break valve opened | = 0 s | * | | | Low-pressure scram signal | < 12.96 MPa | * | | | Secondary system isolation | Scram signal | * | | | Initiation of primary coolant pump coastdown | Scram signal | * | | | Initiation of core power decay curve simulation | Scram signal | * | | | Initiation of HPI coolant injection into pressure vessel upper plenum | > 750 K | * | | | Break valve closed | < 5 MPa | * | * | | Power constant | < 5 MPa | | * | | Termination of HPI coolant injection into pressure vessel upper plenum | · | | * | | SG’s relief valve depressurization | · | | * | | Secondary system isolation | < 3.9 MPa | | * | | Break valve reopened | > 4.5 MPa | | * | * | SG depressurization as AM action | > 623 K | | | * | Initiation of AFW in both loops | AM action signal | | | * | Initiation of ACC system in both loops | < 2.6 MPa | | | * | Termination of ACC system in both loops | < 1.2 MPa | | | * | Initiation of LPI system in both loops | < 1 MPa | | | * |
|
|