Research Article

Nuclear Power Plant Maintenance Optimization with Heuristic Algorithm

Table 7

Obtained optimal test placement times for case scenario 2, no constraints considered.

No.Basic eventTP (hr)

1AFW-TDP-FR-2P6HR590.51
2AFW-MDP-FR-3A6HR2067.71
3AFW-MDP-FR-3B6HR535.95
4AFW-CKV-OO-CV142917.45
5AFW-CKV-OO-CV172280.32
6AFW-CKV-OO-CV15761.18
7ACP-BAC-ST-4KV1H1178.26
8ACP-BAC-ST-4KV1J2169.04
9DCP-BDC-ST-BUS1A970.98
10DCP-BDC-ST-BUS1B816.23

(hr)2187.71
SET (hr)7481.65