Research Article

A Nuclear Reactor Transient Methodology Based on Discrete Ordinates Method

Table 8

Normalized power versus time with different time step in TWIGL problem during ramp perturbation.

0.02 ms0.05 ms0.1 ms0.5 msReference

0 s11111
0.1 s1.313 1.313 1.312 1.309 1.307
0.2 s1.976 1.976 1.975 1.952 1.957
0.3 s2.096 2.097 2.097 2.091 2.074
0.4 s2.114 2.114 2.115 2.114 2.096
0.5 s2.132 2.132 2.133 2.123 2.109
Calculation time (s)8342249