Research Article

Procedure of Active Residual Heat Removal after Emergency Shutdown of High-Temperature-Gas-Cooled Reactor

Table 2

Criterion for ARHRP.

PositionDescriptionValue

CoreHelium flow rate<10% design value
Inlet helium temperature >100°C
SG (A)Temperature difference between tube sheet and steam pipe<100°C
Temperature variation rate <5°C/min
SG (B)Temperature variation rate <5°C/min
SG (C)Temperature variation rate <5°C/min
Maximum temperature <650°C