Research Article
Procedure of Active Residual Heat Removal after Emergency Shutdown of High-Temperature-Gas-Cooled Reactor
Table 2
Criterion for ARHRP.
| Position | Description | Value |
| Core | Helium flow rate | <10% design value | Inlet helium temperature | >100°C | SG (A) | Temperature difference between tube sheet and steam pipe | <100°C | Temperature variation rate | <5°C/min | SG (B) | Temperature variation rate | <5°C/min | SG (C) | Temperature variation rate | <5°C/min | Maximum temperature | <650°C |
|
|