Research Article

Analysis on Steady-State Operation and Heat Loss of Chinese Integrated Pressurized Water Reactor

Table 1

Comparison of calculation results between package subroutine and IAPWS-IF97.

Region Parameters Given by (kJ kg−1)

Region 1 = 300 KIF97115.331273
= 3 MPaPackage115.33127302
= 300 KIF97184.142828
= 80 MPaPackage184.14282773

Region 2 = 300 KIF972549.91145
= 0.0035 MPaPackage2549.9114508
= 2000 KIF976571.22604
= 30 MPaPackage6571.2260386