Design of the VISTA-ITL Test Facility for an Integral Type Reactor of SMART and a Post-Test Simulation of a SBLOCA Test

Table 3

Comparison of the major parameters under a steady state condition.

ParameterSMART design valueMARS results for VISTA-ITL
SMARTVISTA-IdealSMARTVISTA-ActualVISTA-IdealVISTA-Ideal HS

Primary side
Power MWt 3300.419330.00.4190.4190.419
PZR pressure MPa 15.015.015.015.015.015.0
1st flow rate kg/s 20902.662079.22.662.662.66
SG 1st inlet temp. °C 323323323323323323
SG 1st outlet temp. °C 295.7295.7295296296296

Secondary side
SG 2nd inlet press. MPa 6.06.06.06.06.06.0
SG 2nd outlet press. MPa 5.25.25.25.25.25.2
Feed water flow rate kg/s 160.80.204160.80.2010.2040.204
Feed water temp. °C 200.0200.0200.0200.0200.0200.0
Steam temp. °C 298.0298.0291.0307.2298.7298.7