Design of the VISTA-ITL Test Facility for an Integral Type Reactor of SMART and a Post-Test Simulation of a SBLOCA Test
Table 3
Comparison of the major parameters under a steady state condition.
| Parameter | SMART design value | MARS results for VISTA-ITL | SMART | VISTA-Ideal | SMART | VISTA-Actual | VISTA-Ideal | VISTA-Ideal HS |
| Primary side | Power MWt | 330 | 0.419 | 330.0 | 0.419 | 0.419 | 0.419 | PZR pressure MPa | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 | 15.0 | 1st flow rate kg/s | 2090 | 2.66 | 2079.2 | 2.66 | 2.66 | 2.66 | SG 1st inlet temp. °C | 323 | 323 | 323 | 323 | 323 | 323 | SG 1st outlet temp. °C | 295.7 | 295.7 | 295 | 296 | 296 | 296 |
| Secondary side | SG 2nd inlet press. MPa | 6.0 | 6.0 | 6.0 | 6.0 | 6.0 | 6.0 | SG 2nd outlet press. MPa | 5.2 | 5.2 | 5.2 | 5.2 | 5.2 | 5.2 | Feed water flow rate kg/s | 160.8 | 0.204 | 160.8 | 0.201 | 0.204 | 0.204 | Feed water temp. °C | 200.0 | 200.0 | 200.0 | 200.0 | 200.0 | 200.0 | Steam temp. °C | 298.0 | 298.0 | 291.0 | 307.2 | 298.7 | 298.7 |
|
|