Research Article
Containment Depressurization Capabilities of Filtered Venting System in 1000 MWe PWR with Large Dry Containment
Table 2
Initial and boundary conditions.
| Parameter | Value |
| Rx power | 2815 [MWth] | CTMT net free volume | 7.73 × 104 [m3] | CTMT design pressure | 0.5 [MPa] | CTMT ultimate pressure | 1.01 [MPa] | CFVS opening/closing set-point | 0.9/0.6 [MPa] 0.5/0.2 [MPa] | CFVS flow rate | 17 kg/s @ 0.9 MPa 10 kg/s @ 0.5 MPa |
|
|