Research Article
Containment Depressurization Capabilities of Filtered Venting System in 1000 MWe PWR with Large Dry Containment
Table 3
Extended SBO sequence of event.
| Event summary | No CFVS | CFVS @ 0.9 MPa | CFVS @ 0.5 MPa |
| SBO occurs Rx Scram No ECCS/spray/aux feed available | 0.0 sec | | | 2nd safetyv cycling | 9.0 sec | | | SG dryout | 50 min | | | Primary safety valve cycling | 50 min | | | Core uncover | 1.6 Hr | | | CET > 1200 F (SAMG entry) | 2.0 Hr | | | Vessel failure | 3.3 Hr | | | CFVS opening/closing | — | 36.8 Hrs/39.0 Hrs 90.1 Hrs/92.2 Hrs | 8.4 Hrs/17.5 Hrs 74.6 Hrs/80.0 Hrs 149.2 Hrs/153.5 Hrs | Containment failure | 58.4 Hrs | No fail | No fail | Calc. end | 168 Hr | | |
|
|