Research Article
The Verification of Coupled Neutronics Thermal-Hydraulics Code NODAL3 in the PWR Rod Ejection Benchmark
Table 4
Maximum deviations of ANCK and NODAL3 compared to the reference solution in 1997 [
27].
| Parameter | Maximum deviation (%) |
| Critical boron concentration, ppm | | ANCK | 0.75 | NODAL3 (adiabatic) | 0.42 | NODAL3 (quasistatic) | 0.42 | Time of power peak, s | | ANCK | 5.26 | NODAL3 (adiabatic) | 26.00 | NODAL3 (quasistatic) | 21.00 | Power peak | | ANCK | 5.17 | NODAL3 (adiabatic) | 17.67 | NODAL3 (quasistatic) | 15.09 | Final power (at 5 s) | | ANCK | 2.54 | NODAL3 (adiabatic) | 3.55 | NODAL3 (quasistatic) | 3.55 | Final average Doppler temperature (at 5 s), °C | | ANCK | Not available | NODAL3 (adiabatic) | 0.51 | NODAL3 (quasistatic) | 0.53 | Maximum fuel temperature (at 5 s), °C | | ANCK | 1.43 | NODAL3 (adiabatic) | 2.90 | NODAL3 (quasistatic) | 3.06 | Final coolant outlet temperature (at 5 s), °C | | ANCK | Not available | NODAL3 (adiabatic) | 5.29 | NODAL3 (quasistatic) | 5.29 |
|
|