Research Article

Input Calibration and Validation of RELAP5 Against CIRCUS-IV Single Channel Tests on Natural Circulation Two-Phase Flow Instability

Table 2

Varied uncertain input parameters in the parametric study for the test section.

Input parameterBase inputVaried values

Inlet temperature (°C)89.088.0; 90.0
Riser heat loss (kW)00.3; 0.5
Power (%)10095; 105
Inlet loss coefficient 0100; 200
Additional outlet static pressure (mbar)010; 20