Input Calibration and Validation of RELAP5 Against CIRCUS-IV Single Channel Tests on Natural Circulation Two-Phase Flow Instability
Table 6
Difference between calculated and experimental values, test I-2.
| Parameters | Calib. input | Varied input parameters | | | Tin −1°C | Tin +1°C | HL R 0 kW | HL R 0.4 kW | Kin −25% | Kin +25% |
| Oscillation period (%) | −0.46% | −5.59% | −17.00% | −3.82% | −8.40% | 2.07% | −4.95% |
| Flow rate (%) | Average | 0.21% | −4.76% | 5.88% | −0.58% | −1.73% | 1.94% | −3.11% | Maximum | 16.58% | 24.70% | 34.25% | 23.42% | 27.39% | 20.18% | 18.03% | Minimum | 26.38% | −4.04% | 13.96% | 16.60% | 7.59% | 27.26% | 8.95% |
| Inlet riser temperature (°C) | Average | −0.41 | −0.66 | −0.11 | −0.44 | −0.55 | −0.42 | −0.43 | Maximum | −1.29 | −1.50 | −1.20 | −1.25 | −1.46 | −1.29 | −1.27 | Minimum | −0.62 | −1.02 | −0.11 | −0.70 | −0.77 | −0.64 | −0.62 |
| Middle riser temperature (°C) | Average | −0.14 | −0.51 | −0.75 | −0.24 | −0.53 | −0.19 | −0.11 | Maximum | −1.26 | −1.35 | −0.80 | −1.17 | −1.27 | −1.16 | −1.27 | Minimum | 0.47 | 0.13 | −0.44 | 0.64 | 0.22 | 0.43 | 0.53 |
| Outlet riser temperature (°C) | Average | −1.18 | −2.14 | −2.47 | −1.53 | −2.63 | −1.12 | −1.59 | Maximum | −1.46 | −1.56 | −1.04 | −1.20 | −1.55 | −1.51 | −1.33 | Minimum | −1.64 | −3.06 | −2.40 | −1.95 | −3.35 | −1.70 | −1.93 |
| Inlet pressure (mbar) | Average | 5.94 | −3.60 | 2.61 | 5.63 | −4.74 | 9.00 | 3.72 | Maximum | 4.59 | −2.78 | 1.00 | 8.44 | −0.46 | 16.21 | 7.31 | Minimum | 12.37 | −4.10 | −10.52 | 3.47 | −8.11 | 21.66 | −2.71 |
|
|
The values in bold are maximum and minimum values obtained in simulations.
|