Research Article
Research and Evaluation for Passive Safety System in Low Pressure Reactor
Table 3
Measured and calculated initial conditions.
| Parameter | Unit | Test | Calculation | Error % |
| Core power | kW | 600 | 600.5 | 0.02 | Pressure | kPa | 398.0 | 396.3 | −0.43 | Loop 1 flow rate | kg/s | 4.339 | 4.396 | 1.3 | Loop 2 flow rate | kg/s | 4.354 | 4.401 | 1.1 | Core inlet fluid temperature | °C | 91.2 | 91.0 | −0.22 | Core outlet fluid temperature | °C | 98.0 | 98.6 | 0.61 | Water level in tank | m | 23.0 | 22.8 | −0.87 |
|
|