Research Article

A Flooding Induced Station Blackout Analysis for a Pressurized Water Reactor Using the RISMC Toolkit

Table 1

Power distribution factors for representative channels and average pellet power.

Core channelPower distribution factorAverage fuel pellet power density (W/m3)

Hot0.33373.90 108
Average0.36993.24 108
Cold0.29642.17 108