Journals
Publish with us
Publishing partnerships
About us
Blog
Science and Technology of Nuclear Installations
Journal overview
For authors
For reviewers
For editors
Table of Contents
Special Issues
Science and Technology of Nuclear Installations
/
2016
/
Article
/
Tab 5
/
Research Article
Time-Dependent Neutronic Analysis of a Power-Flattened Gas Cooled Accelerator Driven System Fuelled with Thorium, Uranium, Plutonium, and Curium Dioxides TRISO Particles
Table 5
Neutronic data at the beginning and at the end of the cycle.
= 1000 MW
Case
1(a)
1(b)
1(c)
2
3
Fission
BOC
692.17
743.24
675.64
615.68
499.92
EOC
263.56
1
234.39
3
248.73
5
179.48
7
78.38
9
EOC
109.81
2
106.88
4
107.48
6
94.01
8
47.34
10
BOC
138.43
148.64
135.13
123.14
99.98
EOC
52.71
46.88
49.75
35.90
15.68
EOC
21.96
21.38
21.50
18.80
9.47
PE [MW]
BOC
7.22
6.73
7.40
8.12
10.00
EOC
18.97
21.33
20.10
27.85
63.77
EOC
45.54
46.77
46.51
53.19
105.60
PF × 10
17
[p/s]
BOC
0.451
0.420
0.462
0.507
0.624
EOC
1.184
1.331
1.255
1.738
3.981
EOC
2.843
2.919
2.903
3.320
6.592
,
, and
= 0.90
1
After 0.75 days.
2
After 25 days.
3
After 1.25 days.
4
After 30 days.
5
After 1.25 days.
6
After 30 days.
7
After 30 days.
8
After 165 days.
9
After 0.5 days.
10
After 2.5 days.