Research Article

NODAL3 Sensitivity Analysis for NEACRP 3D LWR Core Transient Benchmark (PWR)

Table 1

Sensitivity analysis results in radial node number per assembly for case A1.

ParametersCase A1
Node/assemblyReference1 × 12 × 24 × 48 × 8

Critical boron concentration (ppm)567.7569.6
(0.33%)
563.1
(−0.81%)
561.6
(−1.07%)
561.4
(−1.11%)
Power peaking factor2.8572.815
(−1.47%)
2.866
(0.32%)
2.877
(0.70%)
2.878
(0.74%)
Time of power peak, s0.5600.828
(0.268 s)
0.566
(0.006 s)
0.537
(−0.023 s)
0.530
(−0.030 s)
Power peak 1.1800.554
(−53.05%)
1.172
(−0.68%)
1.315
(11.44%)
1.332
(12.88%)
Power at 5 s0.1960.181
(−7.65%)
0.188
(−4.08%)
0.188
(−4.08%)
0.190
(−3.06%)
Averaged Doppler temperature (at 5 s), °C324.3320.7
(−1.11%)
323.3
(−0.31%)
323.5
(−0.25%)
323.9
(−0.12%)
Maximum fuel centerline temperature (at 5 s), °C673.3620.1
(−7.90%)
659.5
(−2.05%)
665.4
(−1.17%)
666.4
(−1.02%)
Coolant outlet temperature (at 5 s), °C293.1306.7
(4.64%)
308.7
(5.32%)
308.9
(5.39%)
309.1
(5.46%)