Sensitivity analysis results in radial node number per assembly for case A1.
| Parameters | Case A1 | Node/assembly | Reference | 1 × 1 | 2 × 2 | 4 × 4 | 8 × 8 |
| Critical boron concentration (ppm) | 567.7 | 569.6 (0.33%) | 563.1 (−0.81%) | 561.6 (−1.07%) | 561.4 (−1.11%) | Power peaking factor | 2.857 | 2.815 (−1.47%) | 2.866 (0.32%) | 2.877 (0.70%) | 2.878 (0.74%) | Time of power peak, s | 0.560 | 0.828 (0.268 s) | 0.566 (0.006 s) | 0.537 (−0.023 s) | 0.530 (−0.030 s) | Power peak | 1.180 | 0.554 (−53.05%) | 1.172 (−0.68%) | 1.315 (11.44%) | 1.332 (12.88%) | Power at 5 s | 0.196 | 0.181 (−7.65%) | 0.188 (−4.08%) | 0.188 (−4.08%) | 0.190 (−3.06%) | Averaged Doppler temperature (at 5 s), °C | 324.3 | 320.7 (−1.11%) | 323.3 (−0.31%) | 323.5 (−0.25%) | 323.9 (−0.12%) | Maximum fuel centerline temperature (at 5 s), °C | 673.3 | 620.1 (−7.90%) | 659.5 (−2.05%) | 665.4 (−1.17%) | 666.4 (−1.02%) | Coolant outlet temperature (at 5 s), °C | 293.1 | 306.7 (4.64%) | 308.7 (5.32%) | 308.9 (5.39%) | 309.1 (5.46%) |
|
|