Research Article

NODAL3 Sensitivity Analysis for NEACRP 3D LWR Core Transient Benchmark (PWR)

Table 2

Sensitivity analysis results in the radial node number per assembly for case C1.

ParameterCase C1
Node/assemblyReference1 × 12 × 24 × 4

Critical boron concentration (ppm)1135.31146.7
(1.00%)
1133.3
(−0.18%)
1129.5
(−0.51%)
Power peaking factor2.1872.176
(−0.50%)
2.188
(0.05%)
2.193
(−0.27%)
Time of power peak, s0.2680.258
(0.010 s)
0.265
(−0.003 s)
0.269
(0.001 s)
Power peak 4.7735.587
(−17.05%)
4.959
(3.90%)
4.685
(−1.84%)
Power at 5 s0.1460.144
(−1.37%)
0.142
(−2.74%)
0.142
(−2.74%)
Averaged Doppler temperature (at 5 s), °C315.9316.4
(0.16%)
315.9
(0.00%)
315.6
(−0.09%)
Maximum fuel centerline temperature (at 5 s), °C676.1686.7
(1.57%)
672.2
(−0.58%)
668.7
(−1.09%)
Coolant outlet temperature (at 5 s), °C291.5309.5
(6.17%)
308.9
(5.97%)
308.7
(5.90%)