Research Article
NODAL3 Sensitivity Analysis for NEACRP 3D LWR Core Transient Benchmark (PWR)
Table 2
Sensitivity analysis results in the radial node number per assembly for case C1.
| Parameter | Case C1 | Node/assembly | Reference | 1 × 1 | 2 × 2 | 4 × 4 |
| Critical boron concentration (ppm) | 1135.3 | 1146.7 (1.00%) | 1133.3 (−0.18%) | 1129.5 (−0.51%) | Power peaking factor | 2.187 | 2.176 (−0.50%) | 2.188 (0.05%) | 2.193 (−0.27%) | Time of power peak, s | 0.268 | 0.258 (0.010 s) | 0.265 (−0.003 s) | 0.269 (0.001 s) | Power peak | 4.773 | 5.587 (−17.05%) | 4.959 (3.90%) | 4.685 (−1.84%) | Power at 5 s | 0.146 | 0.144 (−1.37%) | 0.142 (−2.74%) | 0.142 (−2.74%) | Averaged Doppler temperature (at 5 s), °C | 315.9 | 316.4 (0.16%) | 315.9 (0.00%) | 315.6 (−0.09%) | Maximum fuel centerline temperature (at 5 s), °C | 676.1 | 686.7 (1.57%) | 672.2 (−0.58%) | 668.7 (−1.09%) | Coolant outlet temperature (at 5 s), °C | 291.5 | 309.5 (6.17%) | 308.9 (5.97%) | 308.7 (5.90%) |
|
|