Research Article

NODAL3 Sensitivity Analysis for NEACRP 3D LWR Core Transient Benchmark (PWR)

Table 3

Sensitivity analysis results in the radial node number per assembly for case C2.

ParameterCase C2
Node/assemblyReference1 × 12 × 24 × 48 × 8

Critical boron concentration (ppm)1160.61162.4
(0.16%)
1151.7
(−0.77%)
1148.6
(−1.03%)
1151.8
(−0.76%)
Power peaking factor2.2212.221
(0.00%)
2.237
(0.72%)
2.241
(0.88%)
2.239
(0.81%)
Time of power peak, s0.1000.079
(−0.021 s)
0.134
(0.034 s)
0.189
(0.089 s)
0.200
(0.100 s)
Power peak 1.0711.071
(0.00%)
1.070
(−0.09%)
1.070
(−0.09%)
1.070
(−0.09%)
Power at 5 s1.0301.029
(−0.10%)
1.029
(−0.10%)
1.030
(0.00%)
1.029
(−0.10%)
Averaged Doppler temperature (at 5 s), °C553.5555.1
(0.29%)
555.2
(0.31%)
555.3
(0.33%)
555.3
(0.33%)
Maximum fuel centerline temperature (at 5 s), °C1733.51733.2
(−0.02%)
1745.7
(0.70%)
1748.4
(0.86%)
1747.3
(0.80%)
Coolant outlet temperature (at 5 s), °C324.5336.6
(3.73%)
336.9
(3.82%)
336.9
(3.82%)
336.9
(3.82%)