Research Article

NODAL3 Sensitivity Analysis for NEACRP 3D LWR Core Transient Benchmark (PWR)

Table 6

Sensitivity analysis results in the axial node number per assembly for case C2.

ParameterCase C2
Node/assemblyReference 1 × 182 × 184 × 188 × 18

Critical boron concentration (ppm)1160.6
1151.8
(−0.76%)
1151.9
(−0.75%)
1151.9
(−0.75%)
1151.9
(−0.75%)
Power peaking factor2.2212.237
(0.72%)
2.239
(0.81%)
2.239
(0.81%)
2.239
(0.81%)
Time of power peak, s0.1000.134
(0.034 s)
0.109
(0.009 s)
0.135
(0.035 s)
0.200
(0.100 s)
Power peak 1.0711.070
(−0.09%)
1.071
(0.00%)
1.071
(0.00%)
1.070
(−0.09%)
Power at 5 s1.0301.029
(−0.10%)
1.029
(−0.10%)
1.029
(−0.10%)
1.029
(−0.10%)
Averaged Doppler temperature (at 5 s), °C553.5555.2
(0.31%)
555.3
(0.33%)
555.3
(0.33%)
555.3
(0.33%)
Maximum fuel centerline temperature (at 5 s), °C1733.51745.7
(0.70%)
1747.4
(0.80%)
1747.1
(0.78%)
1747.3
(0.80%)
Coolant outlet temperature (at 5 s), °C324.5336.9
(3.82%)
336.9
(3.82%)
336.9
(3.82%)
336.9