Research Article

NODAL3 Sensitivity Analysis for NEACRP 3D LWR Core Transient Benchmark (PWR)

Table 7

Sensitivity analysis results in the maximum time step for case A2.

ParameterCase A2
Time step (ms)Reference1001010.10.01

Time of power peak, s0.1000.200
(0.100 s)
0.100
(0.000 s)
0.117
(0.017 s)
0.105
(0.005 s)
0.135
(0.035 s)
Power peak 1.0801.077
(−0.28%)
1.076
(−0.37%)
1.076
(−0.37%)
1.076
(−0.37%)
1.076
(−0.37%)
Power at 5 s1.0351.032
(−0.29%)
1.032
(−0.29%)
1.032
(−0.29%)
1.032
(−0.29%)
1.032
(−0.29%)
Averaged Doppler temperature (at 5 s), °C554.6556.0
(0.25%)
556.0
(0.25%)
556.0
(0.25%)
556.0
(0.25%)
556.0
(0.25%)
Maximum fuel centerline temperature (at 5 s), °C1691.81699.2
(0.44%)
1699.3
(0.44%)
1699.3
(0.44%)
1699.3
(0.44%)
1699.3
(0.44%)
Coolant outlet temperature (at 5 s), °C324.6335.1
(3.23%)
335.1
(3.23%)
335.1
(3.23%)
335.1
(3.23%)
335.1