Research Article
NODAL3 Sensitivity Analysis for NEACRP 3D LWR Core Transient Benchmark (PWR)
Table 8
Sensitivity analysis results in the maximum time step for case C1.
| Parameter | Case C1 | Time step (ms) | Reference | 10 | 1 | 0.1 | 0.01 |
| Time of power peak, s | 0.268 | 0.265 (−0.003 s) | 0.265 (−0.003 s) | 0.265 (−0.003 s) | 0.264 (−0.004 s) | Power peak | 4.773 | 4.958 (3.88%) | 4.958 (3.88%) | 4.957 (3.86%) | 4.952 (3.75%) | Power at 5 s | 0.146 | 0.142 (−2.74%) | 0.142 (−2.74%) | 0.142 (−2.74%) | 0.142 (−2.74%) | Averaged Doppler temperature (at 5 s), °C | 315.9 | 315.9 (0.00%) | 315.9 (0.00%) | 315.9 (0.00%) | 315.8 (−0.03%) | Maximum fuel centerline temperature (at 5 s), °C | 676.1 | 672.6 (−0.52%) | 672.0 (−0.61%) | 672.7 (−0.50%) | 671.6 (−0.67%) | Coolant outlet temperature (at 5 s), °C | 291.5 | 308.9 (5.97%) | 308.9 (5.97%) | 308.9 (5.97%) | 308.9 (5.97%) |
|
|