Research Article
NODAL3 Sensitivity Analysis for NEACRP 3D LWR Core Transient Benchmark (PWR)
Table 9
Sensitivity analysis results in the maximum time step for case C2.
| Parameter | Case C2 | Time step (ms) | Reference | 100 | 10 | 1 | 0.1 | 0.01 |
| Time of power peak, s | 0.100 | 0.134 (0.034 s) | 0.099 (−0.001 s) | 0.118 (0.018 s) | 0.099 (−0.001 s) | 0.132 (0.032 s) | Power peak | 1.071 | 1.070 (−0.09%) | 1.070 (−0.09%) | 1.071 (0.00%) | 1.070 (−0.09%) | 1.071 (0.00%) | Power at 5 s | 1.030 | 1.029 (−0.10%) | 1.029 (−0.10%) | 1.029 (−0.10%) | 1.029 (−0.10%) | 1.029 (−0.10%) | Averaged Doppler temperature (at 5 s), °C | 553.5 | 555.2 (0.31%) | 555.2 (0.31%) | 555.2 (0.31%) | 555.2 (0.31%) | 555.2 (0.31%) | Maximum fuel centerline temperature (at 5 s), °C | 1733.5 | 1745.7 (0.70%) | 1745.7 (0.70%) | 1745.7 (0.70%) | 1745.7 (0.70%) | 1745.7 (0.70%) | Coolant outlet temperature (at 5 s), °C | 324.5 | 336.9 (3.82%) | 336.9 (3.82%) | 336.9 (3.82%) | 336.9 (3.82%) | 336.9 (3.82%) |
|
|