Research Article

Three Design Basis Accidents’ Analysis on the HTR-10GT

Table 3

Accident sequence of an initial core induced by station blackout.

EventsHTR-10GTHTR-10

Station blackout occurs, helium blower and turbine shut down0.0 s0.0 s
Absolute sliding rate of the turbine power 28%/min20.020.0
Absolute sliding rate of the system pressure 0.031 MPa/min38.2 s35.8 s
Protection system takes actions to scram39.2 s36.8 s
Time at which fuel temperature reaches a peak31.2 s0.0 s
Peak fuel temperature1066°C1033°C
Time at which system pressure reaches a peak13.2 s78.8 s
Peak system pressure1.6 Mpa3.18 MPa