Research Article
Three Design Basis Accidents’ Analysis on the HTR-10GT
Table 3
Accident sequence of an initial core induced by station blackout.
| Events | HTR-10GT | HTR-10 |
| Station blackout occurs, helium blower and turbine shut down | 0.0 s | 0.0 s | Absolute sliding rate of the turbine power ⩾ 28%/min | 20.0 | 20.0 | Absolute sliding rate of the system pressure ⩾ 0.031 MPa/min | 38.2 s | 35.8 s | Protection system takes actions to scram | 39.2 s | 36.8 s | Time at which fuel temperature reaches a peak | 31.2 s | 0.0 s | Peak fuel temperature | 1066°C | 1033°C | Time at which system pressure reaches a peak | 13.2 s | 78.8 s | Peak system pressure | 1.6 Mpa | 3.18 MPa |
|
|