Accident sequence of an initial core induced by a control rod withdrawal by mistake.

EventsHTR-10GTHTR-10

A control rod begins to withdraw out of the reflectors at a speed of 1 cm/s0.0 s0.0 s
Neutron flux of power level 1.238.85 s11.3 s
Core power reaches a peak37.8 s (24.3 MW)36.4 s (23.5 MW)
Hot helium temperature exceeds its setting point80.1 s (800°C)84.9 s (750°C)
Time at which control rods begin to drop88.1 s92.9 s
Fuel temperature reaches a peak83.5 s (1201°C)93.3 s (1170°C)
Time at which the accident rod is withdrawn out of the reflectors155.0 s155.0 s