Research Article

Three Design Basis Accidents’ Analysis on the HTR-10GT

Table 6

Accident sequence of an equilibrium core induced by a control rod withdrawal by mistake.

EventsHTR-10GTHTR-10

A control rod begins to withdraw out of the reflectors at a speed of 1 cm/s0.0 s0.0 s
Neutron flux of power level 1.2310.5 s10.5 s
Core power reaches a peak39.4 s (31.1 MW)37.9 s (30.3 MW)
Hot helium temperature exceeds its setting point54.9 s (800°C)54.9 s (750°C)
Time at which control rods begin to drop62.9 s62.9 s
Fuel temperature reaches a peak55.7 s (1066°C)64.0 s (1041°C)
Time at which the accident rod is withdrawn out of the reflectors155.0 s155.0 s