Research Article
STH-CFD Codes Coupled Calculations Applied to HLM Loop and Pool Systems
Table 2
Boundary conditions of Test F400 in CIRCE facility.
| | FPS power | HX power | Nominal Ar flow rate [Nl/s] |
| 280°C | 0 kW | 0 kW | Step 1 | 2.0 | Step 7 | 4.6 | Step 2 | 2.4 | Step 8 | 5.0 | Step 3 | 2.8 | Step 9 | 4.2 | Step 4 | 3.2 | Step 10 | 3.2 | Step 5 | 3.8 | Step 11 | 2.2 | Step 6 | 4.2 | | |
|
|