Research Article
Dispersed Two-Phase Flow Modelling for Nuclear Safety in the NEPTUNE_CFD Code
Table 11
Experimental conditions of the EPOCA tests.
| Number of Lady test | Mass flowrate (m3/h) | Pressure downstream (105 Pa) | (105 Pa) | (—) | Sigma (—) | Inlet liquid temperature (°C) |
| 21 | | | | 91.10 | 0.279 | 21.6 | 20 | | | | 89.88 | 0.331 | 21.5 | 19 | | | | 91.33 | 0.430 | 21.5 | 18 | | | | 89.82 | 0.602 | 21.4 | 17 | | | | 89.86 | 0.904 | 21.3 | 16 | | | | 91.19 | 1.040 | 21.2 | 15 | | | | 90.39 | 1.142 | 20.9 |
|
|
with ( = 21.1°C) = 2500 Pa.
|