Research Article

Analysis of NEA-NSC PWR Uncontrolled Control Rod Withdrawal at Zero Power Benchmark Cases with NODAL3 Code

Table 5

Effect of radial node number per FA for fission power and time of peak fission power in Cases A, B, and D.

ParametersResultsReferenceNODAL3 (node number per FA)
1 × 12 × 24 × 4

Case A
Fission power relative to nominal (), %C135.5635.31 (0.70%)35.39 (0.48%)35.39 (0.48%)
Time of maximum fission power, s82.1484.27 (2.59%)83.24 (1.34%)82.81 (0.82%)

Case B
Fission power relative to nominal (), %C1134.80113.77 (15.60%)110.67 (17.90%)110.11 (18.32%)
Time of maximum fission power, s34.3034.70 (1.17%)34.71 (1.20%)34.68 (1.11%)

Case D
Fission power relative to nominal (), %C196.85112.10 (15.75%)109.23 (12.78%)108.81 (12.35%)
Time of maximum fission power, s39.4039.40 (0.00%)39.91 (1.29%)40.01 (1.55%)

Note. The axial node number is 1 × 18 nodes per axial layer; number in parentheses are the absolute value of relative deviation of NODAL3 with the reference.