Analysis of NEA-NSC PWR Uncontrolled Control Rod Withdrawal at Zero Power Benchmark Cases with NODAL3 Code
Table 5
Effect of radial node number per FA for fission power and time of peak fission power in Cases A, B, and D.
Parameters
Results
Reference
NODAL3 (node number per FA)
1 × 1
2 × 2
4 × 4
Case A
Fission power relative to nominal (), %
C1
35.56
35.31 (0.70%)
35.39 (0.48%)
35.39 (0.48%)
Time of maximum fission power, s
82.14
84.27 (2.59%)
83.24 (1.34%)
82.81 (0.82%)
Case B
Fission power relative to nominal (), %
C1
134.80
113.77 (15.60%)
110.67 (17.90%)
110.11 (18.32%)
Time of maximum fission power, s
34.30
34.70 (1.17%)
34.71 (1.20%)
34.68 (1.11%)
Case D
Fission power relative to nominal (), %
C1
96.85
112.10 (15.75%)
109.23 (12.78%)
108.81 (12.35%)
Time of maximum fission power, s
39.40
39.40 (0.00%)
39.91 (1.29%)
40.01 (1.55%)
Note. The axial node number is 1 × 18 nodes per axial layer; number in parentheses are the absolute value of relative deviation of NODAL3 with the reference.