Transient fuel pellet results for Cases A, B, and D.
| Parameters | Results | Reference | NODAL3 | AM | IQM |
| Case A | Maximum fuel temperature at hot pellet centerline, °C | D6 | 631.8 | 632.9 (0.17%) | 639.4 (1.20%) |
| Case B | Maximum fuel temperature at hot pellet centerline, °C | D6 | 478.2 | 460.9 (3.62%) | 462.8 (3.22%) |
| Case D | Maximum fuel temperature at hot pellet centerline, °C | D6 | 451.4 | 457.8 (1.42%) | 458.8 (1.64%) |
|
|
Note. Number in parentheses are the absolute value of relative deviation of NODAL3 with the reference.
|