Research Article
Prediction of Flow and Temperature Distributions in a High Flux Research Reactor Using the Porous Media Approach
Table 2
Peak fuel temperature.
| Model | Peak fuel temperature (K) | Relative error/% |
| Exact model | 345 | / | Thermal nonequilibrium model | 344 | ā0.289 | Thermal equilibrium model | 375 | +8.695 |
|
|