Research Article

Analyses of the TIARA 43 MeV Proton Benchmark Shielding Experiments Using the ARES Transport Code

Table 2

The ratio of calculation to measurement in peak and continuum regions for iron shielding experiments.

Shield thickness (cm)Peak region (35–45 MeV)Continuum region (10–35 MeV)
Experimental
(n/cm2/s)
Calculated
(n/cm2/s)
C/EC/E
(MORSE)
Experimental
(n/cm2/s)
Calculated
(n/cm2/s)
C/EC/E
(MORSE)

104205.535007.871.190.983539.323980.471.121.04
201022.811134.411.111.05822.22782.020.951.05
4050.5348.270.961.1535.8226.820.751.33