Research Article
Analyses of the TIARA 43 MeV Proton Benchmark Shielding Experiments Using the ARES Transport Code
Table 2
The ratio of calculation to measurement in peak and continuum regions for iron shielding experiments.
| Shield thickness (cm) | Peak region (35–45 MeV) | Continuum region (10–35 MeV) | Experimental (n/cm2/s) | Calculated (n/cm2/s) | C/E | C/E (MORSE) | Experimental (n/cm2/s) | Calculated (n/cm2/s) | C/E | C/E (MORSE) |
| 10 | 4205.53 | 5007.87 | 1.19 | 0.98 | 3539.32 | 3980.47 | 1.12 | 1.04 | 20 | 1022.81 | 1134.41 | 1.11 | 1.05 | 822.22 | 782.02 | 0.95 | 1.05 | 40 | 50.53 | 48.27 | 0.96 | 1.15 | 35.82 | 26.82 | 0.75 | 1.33 |
|
|