Research Article
Sensitivity Evaluation of AP1000 Nuclear Power Plant Best Estimation Model
Table 1
The influence of core channel node number on the coolant temperature variation.
| Node number | Reactor inlet temperature (K) | Reactor outlet temperature (K) | Calculated temperature variation (K) | Designed temperature variation (K) | Fractional error |
| 5 | 554.516 | 593.6928 | 39.1768 | 40.4 | 3.03% | 10 | 554.3637 | 594.7499 | 40.3862 | 40.4 | 0.03% | 15 | 554.2802 | 595.3843 | 41.1041 | 40.4 | 1.74% | 20 | 554.1759 | 596.17845 | 42.00255 | 40.4 | 3.97% | 30 | 553.95 | 597.64 | 43.69 | 40.4 | 8.14% | 40 | 553.8906 | 598.1865 | 44.2959 | 40.4 | 9.64% | 50 | 553.8235 | 598.3517 | 44.5282 | 40.4 | 10.22% |
|
|