Research Article
Sensitivity Evaluation of AP1000 Nuclear Power Plant Best Estimation Model
Table 13
The influence of pressurizer node number on the reactor pressure drop.
| Node number | Reactor inlet pressure (MPa) | Reactor outlet pressure (MPa) | Calculated reactor pressure drop (MPa) | Designed reactor pressure drop (MPa) | Fractional error |