Research Article
Sensitivity Evaluation of AP1000 Nuclear Power Plant Best Estimation Model
Table 18
The influence of cross-flow model on the pressure drop in the reactor core.
| Cross-flow model | Core inlet pressure (MPa) | Core outlet pressure (MPa) | Calculated pressure drop in reactor core (MPa) | Designed pressure drop in reactor core (MPa) | Fractional error |
| None | 15.9615 | 15.6468 | 0.3147 | 0.298 | 5.60% | Having | 15.9618 | 15.6470 | 0.3148 | 0.298 | 5.63% |
|
|